The discharge of ballast from the dedicated clean ballast
tanks should be continuously monitored (but not necessarily recorded)
by the oil content meter required by regulation 18.8.3 so that the oil content, if any, in the ballast
water can be observed from time to time. This oil content meter is
not required to come into operation automatically.