17.9 Permanently installed toxic gas detectors
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - 1983 IGC Code - International Code for the Construction and Equipment of Ships Carrying Liquefied Gases in Bulk - Chapter 17 Special Requirements - 17.9 Permanently installed toxic gas detectors

17.9 Permanently installed toxic gas detectors

  17.9.1 Gas sampling lines should not be led into or through gas-safe spaces. Alarms referred to in 13.6.7 should be activated when the vapour concentration reaches the threshold limiting value.

  17.9.2 The alternative of using portable equipment in accordance with 13.6.9 should not be permitted.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.