Notwithstanding the requirements set out elsewhere in the
Convention, the full functionality (operation, control, monitoring
or any combination thereof, as required) of the safety systems listed
below shall be available from the safety centre:
-
.1 all powered ventilation systems;
-
.2 fire doors;
-
.3 general emergency alarm system;
-
.4 public address system;
-
.5 electrically powered evacuation guidance systems;
-
.6 watertight and semi-watertight doors;
-
.7 indicators for shell doors, loading doors and
other closing appliances;
-
.8 water leakage of inner/outer bow doors, stern
doors and any other shell door;
-
.9 television surveillance system;
-
.10 fire detection and alarm system;
-
.11 fixed fire-fighting local application system(s);
-
.12 sprinkler and equivalent systems;
-
.13 water-based systems for machinery spaces;
-
.14 alarm to summon the crew;
-
.15 atrium smoke extraction system;
-
.16 flooding detection systems; and
-
.17 fire pumps and emergency fire pumps.