Cargo spaces, except open deck areas or refrigerated holds,
shall be provided with an approved automatic smoke-detection system
complying with 7.7.1 to indicate
at the control station the location of outbreak of a fire in all normal
operating conditions of the installations and shall be protected by
an approved fixed quick-acting fire-extinguishing system complying
with 7.7.3.3 operable from the
control station.