10 Alert and Indicator
Locations
10.1 Required alert and indicator type and location
should be in accordance with tables 10.1.1 to 10.1.9.
10.2 Applicable regulations in the IMO instruments
referred to should be consulted for additional requirements.
Notes to be applied to tables 10.1.1 to 10.1.9:
|
(1) Abbreviation for priorities and indicators:
|
EM - emergency alarm
|
A - alarm
|
W - warning
|
C - caution
|
I - indication/indicator
|
Abbreviation for presentation:
|
AU - audible alert display (visual may be necessary in
high-noise areas)
|
V - visual alert display
|
AU, V - both audible and visual alert display
|
VI - visual indicator
|
MI - measuring indicator
|
(2) Cargo control station means a position from which the cargo
pumps and valves can be controlled. If a central cargo control station is
not provided, then the alert or indicator should be located in a suitable
position for the operator (such as at the equipment monitored).
|
(3) If a cargo control station is not provided, the alert or
indication should be given at the gas detector device readout
location.
|
(4) Where the types of alerts are not specifically identified
in the IMO instruments referred to, the recommendations of the IMO
Sub-Committee on Bulk Liquids and Gases are enclosed in parentheses, e.g.
(A,V).
|
Table 10.1.1 Location: navigation
bridge
IMO Instruction
|
Function
|
Priority
|
Display
|
Notes
|
SOLAS II-1
|
|
|
|
|
29.11
|
Rudder angle indicator
|
I
|
MI
|
Column 1, table 9.1
|
29.5.2
|
Steering gear power unit power
failure
|
A
|
AU,V
|
Ditto
|
29.8.4
|
Steering control system power
failure
|
A
|
AU,V
|
Ditto
|
29.12.2
|
Low steering gear hydraulic fluid
level
|
A
|
AU,V
|
Ditto
|
30.1
|
Steering gear running
|
I
|
VI
|
Ditto
|
30.3
|
Steering system electric phase
failure/ overload
|
A
|
AU,V
|
Column 1, table 9.3
|
31.2.7, 49.5
|
Propulsion machinery remote control
failure
|
A
|
AU,V
|
Column 1, table 9.2, 9.3
|
31.2.9, 49.7
|
Low propulsion starting air
pressure
|
A
|
AU,V
|
Ditto
|
31.2.10
|
Imminent slowdown or shutdown of
propulsion system
|
A
|
AU,V
|
Column 1, table 9.2
|
52
|
Automatic propulsion shutdown
override
|
I
|
VI
|
Column 1, table 9.3
|
52
|
Automatic shutdown of propulsion
machinery
|
A
|
AU,V
|
Ditto
|
51.1.3
|
Fault requiring action by or
attention of the officer on watch
|
A
|
AU,V
|
Column 1, table 9.3 (machinery
alarm including 53.4.2 and 53.4.3).
|
31.2.8
|
Propeller
speed/direction/pitch
|
I
|
MI
|
Column 1, table 9.2
|
49.6
|
Propeller
speed/direction/pitch
|
I
|
MI
|
Column 1, table 9.3
|
37
|
Engine-room telegraph
|
I
|
VI
|
Ditto
|
13.6.
|
Watertight door position
|
I
|
VI
|
Column 2, table 9.1
|
13.8.2, 16.2
|
|
|
|
|
13-1.2,
13-1.3,
|
|
|
|
|
14.2,15-1.2
|
|
|
|
|
13.7.3.1
|
Watertight door low hydraulic fluid
level
|
A
|
AU,V
|
Ditto
|
13.7.3.1
13.7.3.2
|
Watertight door low gas pressure,
loss of stored energy
|
A
|
AU,V
|
Ditto
|
|
13.7.8
|
Watertight door electrical power
loss
|
A
|
AU,V
|
Ditto
|
35–1.2.6.2
|
High water level alarm
|
A
|
AU
|
!, where required
|
17–1.1.2,
17–1.1.3
|
Opening indicator
|
A
|
AU,V,VI
|
Column 2, table 9.1
|
17–1.2
|
Shell door position
indicator
|
I
|
VI
|
Column 2, table 9.1. Passenger
ships with ro-ro cargo spaces or special category spaces. Recommended
colours; red – door is not fully closed or not secured, green – door is
fully closed and secured.
|
17–1.3
|
Water leakage detection
indicator
|
I
|
VI
|
Column 2, table 9.1. Passenger
ships with ro-ro cargo spaces or special category spaces. For details see
regulation 17-1.3.
|
25.4
|
Water level pre-alarm
|
A
|
AU,V
|
Column 2, table 9.1. Bulk carriers
and single hold cargo ships other than bulk carriers. For details see
resolution MSC.188(79).
|
25.4
|
Water level main-alarm
|
EM
|
AU,V
|
Ditto
|
31.2.5, 49.3
|
Propulsion control station in
control
|
I
|
VI
|
Column 1, table 9.2
|
51.2.2
|
Alarm system normal power supply
failure
|
A
|
AU,V
|
Column 2, table 9.3
|
SOLAS II-2
|
|
|
|
|
4.5.10.1.3
|
Hydrocarbon gas detection in tanker
cargo pump rooms
|
A
|
AU,V
|
Column 2, table 9.1
|
7.4.1,
7.4.2
|
Fire detection in periodically
unattended, automated or remotely controlled machinery space
|
A
|
AU,V
|
Column 2, table 9.2
|
20.3.1.3
|
Loss of required
ventilation
|
A
|
AU,V
|
Column 2, table 9.1
|
9.6.4
|
Fire door position
|
I
|
VI
|
Ditto
|
10.5.6.4
|
Fixed local application
fire-extinguishing system activation
|
A
|
AU,V; VI
|
Column 2, table 9.1. Indication of
the activated zone
|
SOLAS XII
|
|
|
|
|
12.2
|
Water level pre-alarm
|
A
|
AU,V
|
Column 2, table 9.1. Bulk carriers
and single hold cargo ships other than bulk carriers. For details see
resolution MSC.188(79).
|
12.2
|
Water level main-alarm
|
EM
|
AU,V
|
Ditto
|
Resolution A.481(XII)
|
|
|
|
|
Annex 2, paragraph 7.3
|
Personnel alarm
|
A
|
AU,V
|
Column 2, table 9.1
|
Resolution MSC.128(75), Annex
|
|
|
|
|
4.1.2.2, 5.2.2
|
End of BNWAS dormant period
|
I
|
VI
|
Visible from all operational
positions on the bridge where the Officer of the Watch may reasonably be
expected to be stationed.
|
4.1.2.3, 5.2.3
|
BNWAS first stage audible
alarm
|
A
|
AU
|
Tone/modulation characteristics and
volume level should be adjustable during the commissioning.
|
4.4.1
|
Malfunction of, or power supply
failure to, the BNWAS
|
W
|
AU,V
|
|
SOLAS III
|
|
|
|
|
16.9
|
Position of stabilizer
wings
|
I
|
VI
|
Column 2, table 9.1
|
SOLAS V
|
|
|
|
|
19.2.5.4
|
Rudder angle, propeller
revolutions, the force and direction of thrust and, if applicable, the force
and direction of lateral thrust and the pitch and operational mode.
|
1
|
MI
|
Column 1, table 9.1
|
Gas or chemical codes
|
|
|
|
Column 2, table 9.1 for the
following:
|
IBC 15.2.4
BCH 4.19.4
|
High and low temperature of cargo
and high temperature of heat-exchanging medium
|
A
|
AU,V
|
Ammonium nitrate solution
|
IBC 15.5.1.6
BCH 4.20.6
|
High temperature in tanks
|
A
|
AU,V,MI
|
Hydrogen peroxide solution over 60%
but not over 70%
|
IBC 15.5.1.7
BCH 4.20.7
|
Oxygen concentration in void
spaces
|
A
|
AU,V,MI
|
Hydrogen peroxide solution over 60%
but not over 70%
|
IBC 15.8.23.1
BCH 4.7.15(a)
|
Malfunctioning of temperature
controls of cooling systems
|
A
|
(AU,V)
|
!, Propylene oxide
|
IGC 13.4.1
GC 13.4.1
|
High and low pressure in cargo
tank
|
A
|
AU,V
|
High and low pressure
alarms
|
IGC 13.6.4, 17.9
GC 13.6.4, 17.11
|
Gas detection equipment
|
A
|
AU,V
|
|
IGC
13.5.2
GC 13.5.2
|
Hull or insulation
temperature
|
A
|
AU, (V), MI
|
!
|
IGC 17.18.4.4
GC 17.12.2(d)(iv)
|
Cargo high pressure, or high
temperature at discharge of compressors
|
A
|
AU,V
|
Methylacetylene-propadiene
mixtures
|
IGC
17.14.4.3
GC 17.12.5(d)(iii)
|
Gas detecting system monitoring
chlorine concentration
|
A
|
AU,V
|
!
|
IGC
17.14.4.4
GC 17.12.5(d)(iv)
|
High pressure in chlorine cargo
tank
|
A
|
AU, (V)
|
!
|
IBC 15.5.2.5
BCH 4.20.19
|
High temperature in tanks
|
A
|
AU,V,MI
|
Hydrogen peroxide solution over 8%
but not over 60%
|
IBC 15.5.2.6
BCH 4.20.20
|
Oxygen concentration in void
spaces
|
A
|
AU,V,MI
|
Ditto
|
IBC 15.10.2
BCH 4.3.1(b)
|
Failure of mechanical ventilation
of cargo tanks
|
A
|
(AU,V)
|
!, Sulphur (molten)
|
IGC 5.2.1.7, GC 5.2.5(b)
|
Liquid cargo in the ventilation
system
|
A
|
(AU,V)
|
|
IGC 8.4.2.1, GC 8.4.2(a)
|
Vacuum protection of cargo
tanks
|
A
|
(AU,V)
|
!
|
IGC
9.5.2, GC 9.5.2
|
Inert gas pressure
monitoring
|
A
|
(AU,V)
|
!
|
IGC
13.6.11
GC 13.6.11
|
Gas detection equipment
|
A
|
(AU,V)
|
!
|
IGC 17.14.1.4
GC 17.12.5(a)(iv)
|
Gas detection after bursting disk
for chlorine
|
A
|
(AU,V)
|
!
|
SFV Protocol 1993 Chapter IV
|
|
|
|
|
4(5),
8(1)(e)(iii)
|
Machinery failure advance
alarm
|
A
|
AU,V
|
Column 1, table 9.3 Column 2, table
9.2
|
6(2)
|
Oil-fired steam boiler low water
level, air supply failure or flame failure
|
A
|
AU,V
|
!, Column 2, table 9.3 II-1/32.2
(see table 8.1.2)*
|
8(1)(d)
|
Propulsion control station in
control
|
I
|
|
Column 1, table 9.2 II-1/31.2.5;
49.3*
|
8(1)(e)(i), 8(1)(e)(ii)
|
Propeller
speed/direction/pitch
|
I
|
MI
|
Column 1, table 9.2
II-1/31.2.8*
|
8(1)(g)
|
Propulsion machinery remote control
failure
|
A
|
AU,V
|
Column 1, table 9.2
II-1/31.2.7*
|
8(1)(h)
|
Low propulsion starting air
pressure
|
A
|
A, UV
|
!, Column 1, table 9.2
II-1/31.2.9*
|
13(3)
|
Rudder angle indicator
|
I
|
MI
|
Column 1, table 9.1
II-1/29.11*
|
13(4)
|
Steering gear power unit power
failure
|
A
|
AU,V
|
Column 1, table 9.1
II-1/29.5.2*
|
13(5)
|
Steering gear running
|
I
|
VI
|
Column 1, table 9.1
II-1/30.1*
|
13(5)
|
Steering gear overload/no
volts
|
A
|
AU,V
|
Column 1, table 9.1
II-1/30.3*
|
15(5)
|
Refrigerating machinery spaces
alarm
|
A
|
AU,V
|
Column 2, table 9.1
|
19(1)
|
HP fuel oil pipe leakage
|
A
|
AU,V
|
!, Column 2, table 9.3
|
19(3)
|
Fuel heating high temperature
alarm
|
A
|
AU,V
|
!, Column 2, table 9.3
|
19(5)
|
Fuel detection alarm
|
A
|
AU,V
|
!, Column 2, table 9.3
|
20(1)
|
Bilge high water level alarm
|
A
|
AU,V
|
Column 2, table 9.3
II-1/21.1.6.2*
|
22(2)(a)
|
Essential and important machinery
parameters
|
A
|
AU,V
|
Column 2, table 9.3 II-1/51.1.1
(see table 8.1.2)*
|
22(2)(d)
|
Fault requiring action by or
attention of the officer on watch
|
A
|
AU,V
|
Column 1, table 9.3 (machinery
alarm including 22(2)(c), 23(2), 23(3)(c) and 23(3)(d)) II-1/51.1.3*
|
22(3)(b)
|
Alarm system normal power supply
failure
|
A
|
AU,V
|
Column 1, table 9.3
II-1/51.2.2*
|
24
|
Automatic propulsion shutdown
override
|
I
|
VI
|
Column 1, table 9.3
II-1/52*
|
24
|
Automatic shutdown of propulsion
machinery
|
A
|
AU,V
|
Column 1, table 9.3
II-1/52*
|
Chapter V
|
14(2)(b)
|
Fire detection or automatic
sprinkler operation
|
A
|
AU,V
|
Column 2, table 9.1
II-2/12.1.2.2*
|
15(2)(b)
|
Fire detection alarm
|
A
|
AU,V
|
Column 2, table 9.1
II-2/40.3;13.1.6*
|
IGS
|
|
|
|
|
3.14.11
|
Low water level alarm
|
A
|
AU,V
|
|
2000 HSC Code
|
7.7.1
|
Automatic smoke detection system in
areas of major and moderate fire hazard and other enclosed spaces in
accommodation not regularly occupied
|
I
|
VI
|
!, Column 2, table 9.2
|
7.7.1
|
Automatic smoke detection and fire
detection (with detectors sensing other than smoke) in main propulsion
machinery room(s) additionally supervised by TV cameras monitored from the
operating compartment
|
I
|
VI
|
Column 2, table 9.2
|
+7.7.1.2
|
Fixed fire detection and fire alarm
systems‘ power loss or fault condition
|
A
|
AU,V
|
Column 2, table 9.2
|
+7.7.1.4
|
Fire detection signal
|
A
|
AU
|
Column 2, table 9.2 at alarm
location easily accessible to crew at all time
|
7.7.1.6
|
Fire detection manually operated
call point section unit indicator
|
A
|
AU,V
|
Column 2, table 9.3
|
7.7.2.1
|
Fire detection for periodically
unattended machinery spaces
|
A
|
AU,V
|
Column 2, table 9.3
II-2/7.4.2*
|
7.8.1.2
|
Fire door position
|
I
|
VI
|
Column 2, table 9.2
II-2/9.6.4*
|
7.8.5.3
|
Loss of required
ventilation
|
A
|
AU,V
|
Column 2, table 9.2
II-2/20.3.1.3*
|
7.9.3.3.3
|
Fire door closing
|
I
|
VI
|
!, Column 2, table 9.2
II-2/9.6.4*
|
7.13.1
|
Manually operated sprinkler system
alarms
|
I
|
M,I
|
!, Column 2, table 9.2
|
7.15
|
Smoke detection system for cargo
spaces
|
I
|
VI
|
!, Column 2, table 9.2
|
9.1.14
|
Liquid cooling system
failure
|
A
|
AU,V
|
!
|
9.2.1
|
Automatic fire detection
system
|
A
|
AU,V
|
Column 2, table 9.3 II-2/7.4.1.2;
7.4.2*
|
9.2.1
|
Bilge alarm
|
A
|
AU,V
|
Column 2, table 9.3 II-1/48.1;
48.2*
|
9.2.1
|
Remote machinery alarm
system
|
A
|
AU,V
|
Column 2, table 9.3
|
9.4.2
|
Fuel line failure
|
A
|
AU,V
|
Column 2, table 9.2
|
9.4.5
|
Lubricating oil pressure or level
falling below a safe level
|
A
|
AU,V
|
Column 2, table 9.2
|
9.5.6
|
Lubricating fluid supply failure or
lubrication fluid pressure loss
|
A
|
AU,V
|
Column 2, table 9.2
|
10.3.12
|
Unattended space bilge
alarm
|
A
|
AU,V
|
!, Column 2, table 9.2
II-1/48.1*
|
11.2.1
|
Failure of any remote or automatic
control system
|
A
|
AU,V
|
Column 2, table 9.3
|
11.4.1
|
Malfunction or unsafe
condition
|
A
|
AU,V
|
!, Column 2, table 9.2
|
11.4.1.1
|
Indication of conditions requiring
immediate action
|
EM
|
AU,V
|
Column 2, table 9.2; distinctive
alarms in full view of crew members
|
11.4.1.2
|
Indication of conditions requiring
action to prevent degradation to an unsafe condition
|
C
|
V
|
Column 2, table 9.2; visual display
to be distinct from that of alarms referred to in 10.4.1.1
|
12.3.9
|
Emergency battery discharge
|
I
|
VI
|
Column 2, table 9.2 II-1/42.5.3;
43.5.3*
|
12.5.1
|
Steering system electric
overload
|
A
|
AU,V
|
!, Column 2, table 9.2
II-1/30.3*
|
12.5.2
|
Steering system electric phase
failure
|
A
|
AU,V
|
Column 2, table 9.2
II-1/30.3*
|
12.6.3
|
Electrical distribution system low
insulation level
|
A or I
|
AU or VI
|
!, Column 2, table 9.2
II-1/45.4.2*
|
13.7
|
Rudder angle indicator and
rate-of-turn indicator
|
I
|
VI
|
Column 2, table 9.2 5.4.3
II-1/29.11*, V/19.2.5.4*
|
13.11.2
|
Propulsion indicator
|
I
|
VI
|
Column 2, table 9.2
|
13.11.3
|
Emergency steering position compass
reading indicator
|
I
|
VI
|
Column 2, table 9.2
|
2009 MODU Code
|
|
|
|
|
7.4.1
|
Propeller pitch indicator
|
I
|
VI
|
Column 2, table 9.1
|
7.4.2.5, 8.5.5
|
Propulsion station in control
indication
|
I
|
VI
|
Columns 1 & 3, table 9.2
II-1/31.2.5; 49.3*
|
7.4.2.7, 8.5.7
|
Propulsion machinery remote control
failure
|
A
|
AU,V
|
Column 1, table 9.2 II-1/31.2.7;
49.5*
|
7.4.2.8
|
Propeller
speed/direction/pitch
|
I
|
MI
|
Column 1, table 9.2
II-1/31.2.8*
|
7.4.2.9, 8.5.9
|
Low starting air pressure
|
A
|
AU,V
|
Columns 1 & 3, table 9.2
II-1/31.2.9; 49.7*
|
7.4.2.10
|
Imminent slowdown or shutdown of the
propulsion
|
A
|
AU,V
|
Column 1, table 9.2
|
7.5.17
|
Rudder angle indicator
|
I
|
MI
|
Column 1, table 9.1
II-1/29.11*
|
7.6.1
|
Steering gear running
|
I
|
VI
|
Columns 1 and !3, table 9.1
II-1/30.1*
|
7.6.3
|
Steering gear phase failure/overload
alarm
|
A
|
AU,V
|
Column 1, table 9.3
II-1/30.3*
|
8.5.8
|
Propeller
speed/direction/pitch
|
I
|
MI
|
Column 1, table 9.3
II-1/49.6*
|
8.7.1
|
Fault requiring attention
|
A
|
AU,V
|
Column 1, table 9.3, including
8.3.5.1, 8.4.1, 8.8.6 and 8.9 II-1/51.1.3*
|
8.7.3
|
Alarm system normal supply
failure
|
A
|
AU,V
|
Column 2, table 9.3
II-1/51.2.2*
|
9.10.1
|
Fire detection system alarm
|
A
|
AU,V
|
Column 2, table 9.1
|
9.11.1, 9.12.1
|
Gas detection and alarm
system
|
A
|
AU,V
|
!, Column 2, table 9.1
|
FSS Code
|
|
|
|
|
+8.2.5.2.1, +9.2.5.1.2, 9.2.5.1.3
|
Fire detection or automatic
sprinkler operation
|
A
|
AU,V
|
Column 2, table 9.1
|
+8.2.5.2.1,
+9.2.5.1.5,
+9.2.5.1.2
|
Fire detection system fault
|
A
|
AU,V
|
Ditto
|
10.2.4.1.4
|
Smoke detection system power
loss
|
A
|
AU,V
|
Ditto
|
+10.2.4.1.3, +10.2.2.3
|
Smoke detection
|
A I
|
A,V, VI
|
Ditto
|
15.2.4.2.3.1
|
Inert gas supply main
pressure
|
I
|
MI
|
Ditto; forward of non-return
devices.
|
15.2.4.2.3.1
|
Inert gas pressure
|
I
|
MI
|
Column 2, table 9.1. In slop tanks
of combination carriers
|
* Cross-reference
to SOLAS regulation.
|
+ These alarms
may be omitted if they are provided at the central fire control
station.
|
** Watertight
door alarms may be grouped in one common failure alarm for each door
provided that individual alarms are available at the watertight door
emergency control positions above the bulkhead deck.
|
! No location
specified in other IMO instruments. Location is recommended.
|
Table 10.1.2 Location: machinery
space/machinery control room
IMO Instrument
|
Function
|
Priority
|
Display
|
Notes
|
SOLAS II-1
|
|
|
|
|
29.12.2
|
Low steering gear fluid
level
|
A
|
AU,V
|
Column 3, table 9.1
|
30.1
|
Steering gear running
|
I
|
VI
|
Ditto
|
30.3
|
Steering system electric phase
failure or overload
|
A
|
AU,V
|
Ditto
|
31.2.7,49.5
|
Propulsion machinery remote control
failure
|
A
|
AU,V
|
Column 3, tables 9.2 and
9.3
|
31.2.9,49.7
|
Low propulsion starting air
pressure
|
A
|
AU,V
|
Ditto
|
32.2
|
Oil-fired boiler low water level,
air supply failure, or flame failure
|
A
|
AU,V
|
Column 3, table 9.1
|
32.3
|
Propulsion boiler high water
level
|
A
|
AU,V
|
Ditto
|
31.2.5, 49.3
|
Propulsion control station in
control
|
I
|
VI
|
Column 3, table 9.2
|
37
|
Engine-room telegraph
|
I
|
VI
|
Column 3, table 9.1
|
31.2.4, 49.2
|
Propulsion machinery orders from
bridge
|
I
|
VI
|
Column 3, table 9.2
|
47.1.1,
47.1.2
|
Boiler and propulsion machinery
internal fire
|
A
|
AU,V
|
Column 3, table 9.3
|
47.2
|
Internal-combustion engine
monitors
|
I
|
MI
|
Ditto
|
48.1,
48.2
|
Bilge monitors
|
A
|
AU,V
|
Ditto
|
51.2.2
|
Alarm system normal power supply
failure
|
I
|
AU,V
|
Ditto
|
53.4.3, 51.1.1
|
Essential and important machinery
parameters
|
A
|
AU,V
|
Column 3, table 9.3 (machinery
alarm)
|
42.5.3, 43.5.3
|
Emergency battery discharge
|
I
|
VI
|
Column 3, table 9.1
|
52
|
Automatic shutdown of propulsion
machinery
|
A
|
AU,V
|
Column 3, table 9.3
|
52
|
Automatic propulsion shutdown
override
|
I
|
VI
|
Ditto
|
53.4.2
|
Automatic change-over of propulsion
auxiliaries
|
A
|
AU,V
|
Ditto
|
45.4.2
|
Electrical distribution system low
insulation level
|
A or I
|
AU or I
|
!, Column 3, table 9.1
|
SOLAS II-2
|
|
|
|
|
7.4.1,
7.4.2
|
Fire detection in periodically
unattended, automated or remotely controlled machinery space
|
A
|
AU,V
|
Column 3, table 9.2
|
4.2.2.5.2
|
High-pressure fuel oil
leakage
|
A
|
AU,V
|
Column 3, table 9.3
|
4.2.5.2
|
Service fuel oil tank high
temperature
|
A
|
AU,V
|
Ditto
|
4.5.10.1.3
|
Hydrocarbon gas detection in
tankers cargo pump rooms
|
A
|
AU,V
|
Column 3, table 9.1
|
10.5.6.4
|
Fixed local application
fire-extinguishing system activation
|
A I
|
AU,V I
|
Column 3, table 9.1 Indication of
the activated zone
|
Gas or chemical codes
|
|
|
|
|
IGC 16.3.1.1
GC 16.2(a)
|
Loss of inert gas pressure between
pipes
|
A
|
AU,V
|
!, Column 3, table 9.1
|
IGC 16.3.10
GC 16.10
|
Cargo gas/fuel system gas
detection
|
A
|
AU,V
|
!, Ditto
|
IGC 16.3.1.2
GC 16.2(b)
|
Flammable gas in ventilation
duct
|
A
|
(AU,V)
|
!, Ditto
|
IGC 16.3.4
GC 16.5
|
Flammable gas in ventilation
casing
|
A
|
(AU,V)
|
!, Ditto
|
Resolution A.481(XII)
|
|
|
|
|
Annex 2, paragraph 7.3
|
Personnel alarm
|
A
|
AU,V
|
Column 3, table 9.1
|
SFV Protocol 1993 Chapter IV
|
|
|
|
|
6(2)
|
Oil-fired steam boiler low water
level, air supply failure or flame failure
|
A
|
AU,V
|
! II-1/32.2*
|
8(1)(e)(iii)
|
Machinery failure advance
alarm
|
A
|
AU,V
|
!
|
8(1)(d)
|
Propulsion control station in
control
|
I
|
VI
|
Column 3, table 9.2 II-1/31.2.5;
49.3*
|
8(1)(g)
|
Propulsion machinery remote control
failure
|
A
|
AU,V
|
!, Column 3, table 9.2
II-1/31.2.7*
|
8(1)(h)
|
Low propulsion starting air
pressure
|
A
|
AU,V
|
!, Column 3, table 9.2
II-1/31.2.9*
|
15(4)(b)
|
Refrigerant leak alarm
|
A
|
AU,V
|
|
17(6)
|
Emergency battery discharge
|
I
|
VI
|
!, Column 3, table 9.1
II-1/42.5.3*
|
18(4)(b)
|
Electrical distribution system low
insulation level
|
A
|
AU or VI
|
!, Column 3, table 9.1
II-1/45.4.2*
|
19(7)
|
Internal-combustion engine
monitors
|
I
|
MI
|
Column 3, table 9.3
II-1.47.2*
|
22(2)(a)
|
Essential and important machinery
parameters
|
A
|
AU,V
|
Column 3, table 9.3
II-1/51.1.1*
|
22(3)(b)
|
Alarm system normal power supply
failure
|
A
|
AU,V
|
Column 3, table 9.3
II-1/51.1.1*
|
23(2)
|
Automatic change-over of propulsion
auxiliaries
|
A
|
AU,V
|
Column 3, table 9.3
II-1/53.4.2*
|
24
|
Automatic shutdown of propulsion
machinery
|
A
|
AU,V
|
Column 3, table 9.3 II-1/52*
|
24
|
Automatic propulsion shutdown
override
|
I
|
VI
|
Column 3, table 9.3
II-1/52*
|
IGS
|
|
|
|
|
3.14.11
|
Low water level alarm
|
A
|
AU,V
|
Column 3, table 9.1
|
MARPOL 73/78 Annex I
|
|
|
|
|
16(5)
|
Alarm for excessive oil content in
oily mixture discharge into the sea
|
A
|
(AU,V)
|
!
|
2000 HSC Code
|
|
|
|
|
7.7.2.1.4
|
Fire detection signal
|
A
|
AU,V
|
Column 3, table 9.2
|
7.7.3.1
|
Fire detection for periodically
unattended machinery spaces
|
A
|
AU,V
|
Column 3, table 9.3
II-2/7.4.2*
|
9.2.1
|
Automatic fire detection
system
|
A
|
AU,V
|
Column 3, table 9.3 II-2/7.4.1.2;
7.4.2*
|
9.2.1
|
Bilge alarm
|
A
|
AU,V
|
Column 3, table 9.3 II-1/48.1;
48.2*
|
9.2.1
|
Remote machinery alarm
system
|
A
|
AU,V
|
Column 3, table 9.3
|
9.4.2
|
Fuel line failure
|
A
|
AU,V
|
Column 3, table 9.2
|
9.4.5
|
Lubricating oil pressure or level
falling below a safe level
|
A
|
AU,V
|
Column 3, table 9.2
|
9.5.6
|
Lubricating fluid supply failure or
lubrication fluid pressure loss
|
A
|
AU,V
|
Column 3, table 9.2
|
10.2.7.3
|
High temperature alarm (oil fuel or
settling tank)
|
A
|
V
|
!
|
10.3.12
|
Unattended space bilge
alarm
|
A
|
V
|
!, Column 3, table 9.2,
II-1/48.1*
|
11.2.1
|
Failure of any remote or automatic
control system
|
A
|
AU,V
|
Column 3, table 9.3
|
11.4.1
|
Malfunction or unsafe
condition
|
A
|
AU,V
|
Column 3, table 9.2
|
11.4.1.3
|
Indication of conditions in
11.4.1.1 requiring immediate action
|
A
|
AU,V
|
|
11.4.1.3
|
Indication of conditions in 11.4.1.2
requiring action to prevent degradation to an unsafe condition
|
A
|
AU,V
|
Column 3, table 9.2; visual display
to be distinct from that of alarms referred to in 10.4.1.1
|
11.5
|
Shutdown system activation
|
A
|
AU,V
|
!, Column 3, table 9.2
|
12.5.1
|
Steering system electric
overload
|
A
|
AU,V
|
!, Column 3, table 9.2
II-1/30.3*
|
12.5.2
|
Steering system electric phase
failure
|
A
|
AU,V
|
Column 3, table 9.2,
II-1/30.3*
|
12.6.3
|
Electrical distribution system low
insulation level
|
A or I
|
AU or VI
|
!, Column 3, table 9.2
II-1/45.4.2*
|
2009 MODU Code
|
|
|
|
|
4.3.7
|
Machinery failure pre-alarm
|
A
|
AU,V
|
!, Column 3, table 9.1
|
4.6.2
|
Manual overriding of the automatic
control indicator
|
I
|
VI
|
Column 3, table 9.1
|
5.4.12
|
Emergency battery discharge
|
I
|
VI
|
Column 3, table 9.1
II-1/42.5.3*
|
5.6.7
|
Electrical distribution system low
insulation level
|
A or I
|
AU or VI
|
!, Column 3, table 9.1
II-1/45.4.2*
|
7.3.1
|
Water tube boiler high water level
alarm
|
A
|
AU,V
|
Column 3, table 9.1
|
7.4.2.4, 8.5.4
|
Propulsion machinery orders from
bridge
|
I
|
VI
|
Column 3, table 9.2 II-1/31.2.4;
49.2*
|
7.4.2.5, 8.5.5
|
Propulsion station in control
indication
|
I
|
VI
|
Columns 1 and 3, table 9.2
II-1/31.2.5; 49.3*
|
7.4.2.9
|
Low starting air pressure
|
A
|
AU,V
|
Columns 1 and 3, table 9.2
II-1/31.2.9*
|
7.4.2.10
|
Imminent slowdown or shutdown of the
propulsion system
|
A
|
AU,V
|
Column 1, table 9.2
|
7.6.1
|
Steering gear running
|
I
|
VI
|
Columns 1 & !3, table 9.1
II-1/30.1*
|
8.3.1
4.8.7
|
HP fuel oil pipe leakage
|
A
|
AU,V
|
!, Column 3, table 9.3
II-2/4.2.2.5.2*
|
8.3.3
|
Fuel heating temperature
alarm
|
A
|
AU,V
|
!, Column 3, table 9.3
II-2/4.2.5.2*
|
8.3.6
|
Fire detection alarm for
boiler/propulsion machinery
|
A
|
AU,V
|
!, Column 3, table 9.3
II-1/47.1*
|
8.3.7
|
Internal-combustion engine
monitors
|
I
|
MI
|
Column 3, table 9.3
II-1/47.2*
|
8.5.7
|
Propulsion machinery remote control
failure
|
A
|
AU,V
|
Column 3, table 9.3
II-1/49.5*
|
8.7.1
|
Fault requiring attention
|
A
|
AU,V
|
At a normally manned control
station in addition to main machinery control station including 8.3.5.1,
8.4.1, 8.8.6 and 8.9 II-1/51.1*
|
8.8.2
|
Automatic change-over of propulsion
auxiliaries
|
A
|
AU,V
|
Column 3, table 9.3
II-1/53.4.2*
|
FSS Code
|
|
|
|
|
15.2.4.3.3
|
Inert gas system:
|
|
|
Column 3, table 9.1
|
15.2.4.3.1.1
|
- low water pressure/flow
|
A
|
AU,V
|
|
15.2.4.3.1.2
|
- high water level
|
A
|
AU,V
|
|
15.2.4.3.1.3
|
- high gas temperature
|
A
|
AU,V
|
|
15.2.4.3.1.4
|
- blower failure
|
A
|
AU,V
|
|
15.2.4.3.1.5
|
- oxygen content
|
A
|
AU,V
|
|
15.2.4.3.1.6
|
- power supply failure
|
A
|
AU,V
|
|
15.2.4.3.1.7, 15.2.2.4.6
|
- water seal low level
|
A
|
AU,V
|
|
15.2.4.3.1.8, 15.2.4.3.4
|
- low gas pressure
|
A
|
AU,V
|
|
15.2.4.3.1.9
|
- high gas pressure
|
A
|
AU,V
|
|
15.2.4.3.2
|
gas generator failure:
|
|
|
|
15.2.4.3.2.1
|
- low fuel supply
|
A
|
AU,V
|
|
15.2.4.3.2.2
|
- power supply failure
|
A
|
AU,V
|
|
15.2.4.3.2.3
|
- control power failure
|
A
|
AU,V
|
|
15.2.4.2.3.2
|
Inert gas O2
content
|
I
|
MI
|
Ditto
|
* Cross-reference
to SOLAS regulation.
|
! No location
specified in other IMO instruments. Location is recommended.
|
Table 10.1.3 Location: central
fire control station where provided
IMO Instrument
|
Function
|
Priority
|
Display
|
Notes
|
SOLAS II-2
|
|
|
|
|
+7.4.1, 7.4.2
|
Fire detection in periodically unattended, automated
or remotely controlled machinery space
|
A
|
AU,V
|
|
SFV Protocol
1993 Chapter V
|
|
|
|
|
14(3)(c)
|
Automatic sprinkler system pressure
|
I
|
MI
|
|
2000 HSC Code
|
|
|
|
|
+7.7.2.1.2
|
Fixed fire detection and alarm systems‘ power
loss or fault condition
|
A
|
AU,V
|
|
+7.7.2.1.4
|
Fire detection signal
|
A
|
AU,V
|
|
2009 MODU Code
|
|
|
|
|
9.10.1
|
Fire detection
system
|
A I
|
AU,V VI
|
|
9.11.1, 9.12.1
|
Gas
detection and alarm systems
|
A
|
A,V
|
!
|
FSS Code
|
|
|
|
|
8.2.4.2.5
|
Automatic
sprinkler system pressure
|
I
|
MI
|
|
+8.2.5.2.1, +9.2.5.1.2, +9.2.5.1.3
|
Fire detection or automatic sprinkler operation
|
A
|
AU,V
|
|
+8.2.5.2.1, +9.2.5.1.5, +9.2.5.1.2
|
Fire detection system fault
|
A
|
AU,V
|
|
+10.2.4.1.4
|
Smoke detection
system power loss
|
A
|
AU,V
|
|
+10.2.4.1.3, +10.2.2.3
|
Smoke detection
|
A I
|
AU,V VI
|
|
* Cross-reference
to SOLAS regulation.
|
+ These alarms
may be omitted if the central fire control station is on the navigation
bridge.
|
Table 10.1.4 Location: at the
equipment or at the location being monitored
IMO Instrument
|
Function
|
Priority
|
Display
|
Notes
|
SOLAS II-1
|
|
|
|
|
29.11
|
Rudder angle indicator
|
I
|
MI
|
At the steering gear
compartment
|
15.8.2.1. 15.8.3
|
Shell valve closure
|
I
|
I
|
|
32.6
|
Water level of essential
boiler
|
I
|
MI
|
|
13.7.1.6
|
Watertight door closing
|
EM
|
AU
|
Distinct from other alarms in area;
in passenger areas and high-noise areas, add intermittent visual
alarm
|
13.7.3.2
|
Watertight door loss of stored
energy
|
A
|
AU,V
|
At each local operating
position
|
33.3
|
Steam pressure
|
I
|
MI
|
|
SOLAS II-2
|
|
|
|
|
10.9.1.1.1
IBC 11.2.1
|
Release of fire-extinguishing
medium
|
EM
|
AU
|
Cargo pump-room
|
4.2.2.3.5
|
Fuel oil tank level
|
I
|
MI
|
If provided
|
4.2.2.3.5.1.1
4.2.2.3.5.2
|
Fuel oil tank level
|
I
|
MI
|
|
Gas or Chemical codes
|
|
|
|
|
IGC 9.5.1
GC 9.5.1
|
Content of oxygen in inert gas/trace
of oxygen in nitrogen
|
A
|
(AU,V) MI
|
|
IGC 3.6.3
GC 3.6.3
|
Warning on both sides of the
airlock
|
A
|
AU,V
|
|
IGC 8.2.8.2
GC 8.2.8(b)
|
Indicates which one of the
pressure-relief valves is out of service
|
I
|
VI
|
|
IGC 11.5.2
GC 11.5.2
|
Inerting/extinguishing medium
release
|
EM
|
AU
|
Gas-dangerous enclosed
spaces
|
GC 13.4
|
Cargo pressure
|
I
|
MI
|
Local gauges required by 13.4.1,
13.4.2, 13.4.3 and 13.4.4
|
IGC 13.6, 17.9
GC 13.6, 17.11
|
Gas detection equipment
|
A
|
AU,V
|
|
SFV Protocol 1993 Chapter II
|
|
|
|
|
13(1)
|
Shell valve closure
|
A
|
AU,V
|
II-1/17.9.2.1*
|
13(2)
|
Shell valve closure
|
A
|
AU,V
|
II-1/17.9.3*
|
Chapter IV
|
|
|
|
|
11(7)
|
Collision bulkhead valve
closure
|
I
|
VI
|
II-1/21.2.12*
|
13(3)
|
Rudder angle indicator
|
I
|
MI
|
|
15(4)(a)
|
Refrigerant leak indicator
|
I
|
VI
|
|
15(5)
|
Refrigerating machinery spaces
alarm
|
A
|
AU,V
|
At escape exits
|
Chapter V
|
|
|
|
|
14(3)(c)
|
Automatic sprinkler system
pressure
|
I
|
MI
|
At each section stop valve
|
14(5)(a)
|
Automatic sprinkler tank
level
|
I
|
MI
|
|
15(2)(b)
|
Fire detection alarm
|
A
|
AU
|
To ensure fire alarm sounding on the
deck where the fire is detected
|
IGS
|
|
|
|
|
3.15.3.2.1
|
Effluent drain valve position
indicator
|
I
|
VI
|
!
|
6.2
|
Tank pressure sensors
|
I
|
MI
|
!
|
VEC systems
|
|
|
|
|
2.3.1
|
Isolation valve position
indicator
|
I
|
VI
|
|
2.4.1.3
|
Liquid level indicator
|
I
|
MI
|
At the location where cargo
transfer is controlled
|
2.4.1.4
|
Liquid level indicator
|
I
|
MI
|
Portable gauging device on the
tank
|
3.2.1.3
|
Cargo vapour shutoff valve position
indicator
|
I
|
VI
|
Near terminal vapour
connection
|
3.3.3
|
Terminal vapour pressure sensing
device
|
I
|
MI
|
!, (3)
|
3.3.3.2
|
Terminal vapour pressure
alarm
|
A
|
AU,V
|
!, (3)
|
3.3.3.3
|
Signal for sequential shutdown of
onshore pumps and remotely operated cargo vapour shutoff valve
|
A
|
(AU,V)
|
!, (3)
|
IMDG Code (Vol 1)
|
|
|
|
|
7.7.3.4
|
Cargo control temperature less than
+25°C
|
A
|
AU,V
|
!, Alarms independent of power
supply of the refrigeration system
|
2000 HSC Code
|
|
|
|
|
7.7.3.2.7
|
Release of fire-extinguishing
medium
|
EM
|
AU,V
|
Spaces in which personnel normally
work or to which they have access
|
7.9.3.3.2
|
Fire door closing
|
EM
|
AU
|
Sounding alarm before the door
begins to move and until completely closed
|
7.13.1
|
Manually operated sprinkler system
alarms
|
I
|
M,I
|
!, Column 2, table 9.2
|
10.9.5
|
Bilge cocks and valve position
indication
|
I
|
VI
|
To indicate open or closed
position
|
1995 Driving Code
|
|
|
|
|
2.5.3
|
Diving bell internal
pressure
|
I
|
MI
|
!, At the location of the attendant
monitoring diving operations
|
2.5.5
|
Diving bell, etc., overpressure
alarm
|
A
|
AU,V
|
!, At the location of the attendant
monitoring diving operations
|
2.9.3
|
Diving equipment fire detection
alarm
|
A
|
AU,V
|
!, At the location of the attendant
monitoring diving operations
|
2009 MODU Code
|
|
|
|
|
3.6.5.2
|
Watertight doors and hatch cover
positions alarm
|
A
|
AU,V
|
|
4.4.5
|
Water level of essential
boiler
|
I
|
MI
|
II-1/32.6*
|
4.5.3
|
Steam pressure
|
I
|
MI
|
II-1/33.3*
|
4.9.6
|
Bilge valve indicator
|
I
|
VI
|
II-1/21.2.12*
|
4.10.8
|
Ballast valve position
indicator
|
I
|
VI
|
|
4.12.11
|
Cable tension, windlass power load
and amount of cable paid out
|
I
|
VI
|
|
FSS Code
|
|
|
|
|
5.2.1.3.2
|
Release of fire-extinguishing
medium
|
EM
|
AU
|
|
6.2.4.2.5
|
Automatic sprinkler system
pressure
|
I
|
MI
|
At each section stop valve
|
8.2.3.2.1
|
Automatic sprinkler system tank
level
|
I
|
MI
|
|
15.2.3.1.1
|
Flue gas isolating valve
open/closed
|
I
|
VI
|
|
15.2.4.1
|
Inert gas discharge
temperature/pressure
|
I
|
MI
|
Measured at discharge of gas
blower
|
* Cross-reference
to SOLAS regulation.
|
! No location
specified in other IMO instruments. Location is recommended.
|
Table 10.1.5 Location: engineers'
accommodation
IMO Instrument
|
Function
|
Priority
|
Display
|
Notes
|
SOLAS II-1
|
|
|
|
|
38
|
Engineers‘ alarm
|
A
|
AU
|
Column 4, table 9.1
|
51.1.2,
51.1.5
|
Fault requiring attention of the
engineer on duty
|
A
|
AU,V
|
Ditto (machinery
alarm)
|
SOLAS II-2
|
|
|
|
|
7.4.1,
7.4.2
|
Fire detection in periodically
unattended, automated or remotely controlled machinery space
|
A
|
AU,V
|
Ditto
|
Resolution A.481(XII)
|
|
|
|
|
Annex 2, paragraph 7.3
|
Personnel alarm
|
A
|
AU,V
|
Column 4, table 9.3 (when the
navigation bridge is unmanned)
|
SFV Protocol 1993 Chapter IV
|
|
|
|
|
14
|
Engineers‘ alarm
|
A
|
AU
|
Column 4, table 9.3
II-1/38*
|
22(2)(b)
22(2)(c)
|
Fault requiring attention of
engineer on duty
|
A
|
AU,V
|
Column 4, table 9.3 II-1/51.1.2;
51.1.5*
|
2000 HSC Code
|
|
|
|
|
7.7.2.1
|
Fire detection for periodically
unattended machinery spaces
|
A
|
AU,V
|
Column 4, table 9.3 II-2/7.4.1.1;
7.4.2*
|
2009 MODU Code
|
|
|
|
|
7.8
|
Engineers‘ alarm
|
A
|
AU
|
Column 4, table 9.3 II-1/38*
|
8.7.1
|
Fault requiring
attention
|
A
|
AU
|
Activate engineers‘ alarm
required by 7.8 including 8.3.5.1, 8.4.1, 8.8.6 and 8.9 II-1/51.1.5*
|
* Cross-reference
to SOLAS regulation.
|
Table 10.1.6 Location:
miscellaneous
IMO Instrument
|
Function
|
Priority
|
Display
|
Notes
|
SOLAS II-1
|
|
|
|
|
13.6.13–1.2.13–1.3
|
Watertight door position
|
I
|
VI
|
At operating stations from which the
door is not visible. At all remote operating positions
|
35.1.3.12
|
Bilge cocks and valves
position
|
I
|
VI
|
At their place of operation
|
SOLAS II-2
|
|
|
|
|
7.4.1,
7.4.2
|
Fire detection in periodically
unattended, automated or remotely-controlled machinery space
|
A
|
AU,V
|
Alarm at attended location when
navigation bridge is unmanned
|
7.9.1
|
Fire detection alarm
|
A
|
AU,V
|
Alarm at location to ensure that any
initial fire detection alarm is immediately received by a responsible member
of crew
|
7.9.4
|
Fire (special alarm to summon
crew)
|
EM
|
AU
|
May be part of general emergency
alarm
|
4.5.10.1.3
|
Hydrocarbon gas detection in
tankers cargo pump-rooms
|
A
|
AU,V
|
At the pump-room
|
+4.5.10.1.1
|
Temperature sensing devices for pumps
installed in tankers cargo pump-rooms
|
A
|
AU,V
|
At the pump control station
|
10.5.6.4
|
Fixed local application
fire-extinguishing system activation
|
A
|
AU,V
|
In each protected space. Protected
space is a machinery space where a FWBLAFFS is installed.
|
7.5.2,
7.5.3.1
|
Fire alarm
|
EM
|
AU
|
Audible alarm within the space where
detectors are located.
|
SOLAS III
|
|
|
|
|
6.4.2
|
General emergency alarm
|
EM
|
AU
|
Throughout all the accommodation
and normal crew working spaces
|
SFV Protocol 1993 Chapter II
|
|
|
|
|
2(6)
|
Watertight door position
|
I
|
VI
|
At remote operating position
II-1/15.6.4*
|
4(1)
|
Freezer room weathertight door
position
|
A
|
AU,V
|
!, At the attended location
|
Chapter IV
|
|
|
|
|
15(5)
|
Refrigerating machinery spaces
alarm
|
A
|
AU,V
|
At an attended location (control
station)
|
19(5)
|
Fire detection alarm
|
A
|
AU,V
|
At appropriate spaces when the ship
is in harbour
|
20(1)
|
Bilge high-water level
alarm
|
A
|
AU,V
|
At places where continuous watch is
maintained when navigation bridge is not manned
|
|
|
|
|
II-1/21.1.6.2*
|
Chapter V
|
|
|
|
|
14(2(b)
|
Fire detection or automatic
sprinkler operation
|
A
|
AU,V
|
Alarm at location easily accessible
to crew at all times
|
15(2)(b)
|
Fire detection alarm
|
A
|
AU,V
|
Alarm at location easily accessible
to crew at all times II-2/7.9.1*
|
Resolution MSC.128(75), Annex
|
|
|
|
|
4.1.2.4, 5.2.4
|
BNWAS second stage audible
alarm
|
A
|
AU
|
Locations of the master, officers
and further crew members capable of taking corrective action
|
4.1.2.5, 5.2.4
|
BNWAS third stage audible
alarm
|
A
|
AU
|
Locations of the master, officers
and further crew members capable of taking corrective action. If provided
(ref. 4.1.2.6)
|
SFV Protocol 1993 Chapter VIII
|
|
|
|
|
2(1)
|
General emergency alarm
|
EM
|
AU
|
Throughout all the accommodation
and normal crew working spaces III/6.4.2*
|
Nuclear Merchant Ship Code
|
|
|
|
|
3.9.3
|
Spaces containing NSSS safety
equipment fire detection alarm
|
A
|
AU,V
|
!, Alarm at main control position
and emergency control position
|
6.4.3
|
Controlled areas indication of
radiation levels and airborne contamination
|
I
|
VI
|
At main control position
|
6.10.2
|
Containment structure purge system
radioactivity alarm
|
A
|
AU,V
|
At main control position
|
6.10.4
|
Controlled and supervised areas
exhaust for radioactivity alarm
|
A
|
AU,V
|
At main control position
|
2000 HSC Code
|
|
|
|
|
4.2.1
|
General emergency alarm
|
EM
|
AU
|
Clearly audible throughout all the
accommodation and normal spaces and open decks 8.2.2.2
III/6.4.2*
|
7.7.1.1.4
|
Fire detection signal
|
A
|
AU
|
Clearly audible throughout the crew
accommodation and service spaces
|
7.7.1.1.6
|
Fire detection manually operated
call point section unit indicator
|
A
|
AU,V
|
Alarm at location easily accessible
to crew at all times
|
2009 MODU Code
|
|
|
|
|
3.6.2
|
Watertight boundary valve position
indicator
|
I
|
VI
|
At the remote control
station
|
4.4.2
|
Oil-fired boiler low water level,
air supply failure or flame failure
|
A
|
AU,V
|
Alarm at an attended location
II-1/32.2*
|
4.9.1
|
Presence of water indicator
|
I
|
VI
|
|
4.12.12
|
Cable tension and speed and
direction of wind
|
I
|
VI
|
At a manned station
|
4.14.3.1
|
Jacking system overload alarm, out
of level alarm, rack phase differential alarm (when provided)
|
A
|
AU,V
|
At the jacking system control
station
|
4.14.3.2.1
|
Inclination of the unit on two
horizontal perpendicular axes
|
I
|
MI
|
At the jacking system control
station
|
4.14.3.2.2
|
Power consumption or other
indicators or lifting or lowering the legs, as applicable
|
I
|
MI
|
At the jacking system control
station
|
4.14.3.2.3
|
Brake release status
|
I
|
VI
|
At the jacking system control
station
|
6.3.1.1.3
|
Loss of ventilation
|
A
|
AU,V
|
At a manned station
|
6.3.1.2.3
|
Loss of ventilation
|
A
|
AU,V
|
At a manned station
|
6.3.1.3.3
|
Loss of ventilation
overpressure
|
A
|
AU,V
|
At a manned station
|
8.7.1
|
Fault requiring attention
|
A
|
AU,V
|
Including 8.3.5.1, 8.4.1, 8.8.6 and
8.9 II-1/51.1*
|
9.10.1
|
Fire detection system alarm
|
A
|
AU,V
|
At alarm location easily accessible
to crew at all times
|
9.11.1, 9.12.1
|
Gas detection and alarm
system
|
A
|
AU,V
|
!, Alarm at a location easily
accessible to crew at all times
|
5.7.2
|
General emergency alarm
|
EM
|
AU
|
Clearly perceptible in all parts of
the unit III/6.4.2*
|
13.5.1
|
Wind direction indicator
|
I
|
MI
|
It should be free from the effects
of airflow disturbances caused by nearby objects or rotor downwash and be
visible from a helicopter in flight or in a hover over the helideck
|
13.5.26
|
Status light
|
A
|
V
|
To be visible to the helicopter
pilot from any direction of approach
|
13.6
|
Motion sensing system
|
I
|
MI
|
Display should be located at the
aeromobile VHF radiotelephone station
|
1995 Driving Code
|
|
|
|
|
2.5.2
|
Compression chamber internal
pressure
|
I
|
MI
|
At central control position
|
2.5.3
|
Diving bell external
pressure
|
I
|
MI
|
Within the bell
|
2.9.3
|
Diving equipment fire detection
alarm
|
A
|
AU,V
|
!, At an attended location other
than the above
|
2.11.2
|
Compression chamber/diving bell
parameters
|
I
|
MI
|
At central control position
|
2.11.3
|
Diving bell oxygen and
CO2 levels
|
I
|
MI
|
Within the bell
|
FSS Code
|
|
|
|
|
8.2.5.2.1
|
Fire detection or automatic
sprinkler operation
|
A
|
AU,V
|
Alarm at attended location other
than navigation bridge and central fire control station
|
9.2.5.1.3
|
Fire detection alarm
|
A
|
AU,V
|
Alarm at location easily accessible
to crew at all times
|
9.2.5.1.1
|
Fire detection alarm not receiving
attention
|
EM
|
AU
|
Alarmed to crew; may be part of
general emergency alarm
|
LSA Code
|
|
|
|
|
7.2.1
|
General emergency
alarm
|
EM
|
AU
|
Throughout the
accommodation and normal crew working spaces
|
* Cross-reference
to SOLAS regulation.
|
+ These alarms may
be omitted if they are provided at the cargo control station.
|
Table 10.1.7 Location: cargo
control station
IMO Instrument
|
Function
|
Priority
|
Display
|
Notes
|
SOLAS II-2
|
|
|
|
|
+11.6.3.1
|
Cargo tank high level alarm and
gauging
|
A
|
AU,V MI
|
!, If required
|
+4.5.10.1.1
|
Temperature sensing devices for
pumps installed in tankers cargo pump rooms
|
A
|
AU,V
|
|
4.5.10.1.3
|
Hydrocarbon gas detection in
tankers cargo pump rooms
|
A
|
AU,V
|
|
Gas or Chemical codes
|
|
|
|
|
IBC 8.2.3
BCH 2.13.1
|
High level of the liquid in any
tank
|
A
|
AU,V
|
!, (2)
|
IBC 15.10.2
BCH 4.3.1(b)
|
Failure of mechanical ventilation
system for maintaining low gas concentration in cargo tanks
|
A
|
AU,V
|
!, Sulphur liquid
|
IBC 15.19.2
BCH 4.14.3
|
Power failure on any system
essential for safe loading
|
A
|
AU,V
|
!, (2)
|
IBC 15.19.6
BCH 4.14.1
|
High level alarm, cargo
tank
|
A
|
AU,V
|
!, (2)
|
IGC 13.2.1
GC 13.2.1
|
Cargo level
|
I
|
MI
|
(2)
|
IGC 13.4.1
GC 13.4.1
|
High and low pressure in cargo
tank
|
A
|
MI AU,(V)
|
(2)
|
IGC 13.6.4,
17.9
GC 13.6.4, 17.11
|
Gas detection equipment
|
A
|
AU, (V)
|
|
IGC 17.18.4.4
GC 17.12.2(d)(iv)
|
Cargo high pressure, or high
temperature at discharge of compressors
|
A
|
AU, V
|
(2), Methylacetylenepropadiene
mixtures
|
GC 10.2.2
|
Shutdown of submerged cargo
pumps
|
A
|
(AU,V)
|
|
IGC
17.14.4.3
GC 17.12.5(d)(iii)
|
Gas detecting system monitoring
chlorine concentration
|
A
|
AU,V
|
!, (3)
|
IGC
17.14.4.4
GC 17.12.5(d)(iv)
|
High pressure in cargo
tanks(chlorine)
|
A
|
AU,(V)
|
!, (2)
|
IGC 13.3.1
GC 13.3.1
|
High liquid level in cargo
tank
|
A
|
AU, V
|
!, (2)
|
IGC 13.5.1
GC 13.5.1
|
Cargo temperature
|
I
|
MI
|
!, (2)
|
IGC 13.5.2
GC 13.5.2
|
Hull or insulation
temperature
|
I A
|
MI AU,(V)
|
!
|
IGC 13.5.3
GC 13.5.3
|
Cargo tank temperature
|
I
|
MI
|
!, (2)
|
IGC 13.6.11
GC 13.6.11
|
Gas detection equipment
|
A
|
AU,V MI
|
!, (3)
|
IGC
17.14.1.4
GC 17.12.5(a)(iv)
|
Gas detection after bursting disk
for chlorine
|
A
|
(A,V) MI
|
!, (2)
|
IBC 15.7.10
BCH 4.5.10
|
High level of phosphorus
|
A
|
(AU,V)
|
!, (2)
|
IBC 15.19.7.2
BCH 4.14.2(b)
|
Overflow alarm
|
A
|
AU,V
|
!
|
IGC
5.2.1.7
GC 5.2.5(b)
|
Liquid cargo in the vent
system
|
A
|
(AU,V)
|
!, (2)
|
IGC 8.4.2.1
GC 8.4.2(a)
|
Vacuum protection of cargo
tanks
|
A
|
(AU,V)
|
!, (2)
|
IGC 9.5.2, GC 9.5.2
|
Inert gas pressure
monitoring
|
A
|
(AU,V)
|
!
|
IGS
|
|
|
|
|
3.15.3.2.1
|
Effluent drain valve position
indicator
|
I
|
VI
|
!
|
6.2
|
Tank pressure sensors
|
I
|
MI
|
!, If required
|
VEC Systems
|
|
|
|
|
2.5.2.3
|
Tank overflow alarm
|
A
|
AU,V
|
!, (2)
|
2.5.2.4
|
Signal for sequential shutdown of
onshore pumps or valves or both and of the ships‘ valves
|
A
|
(AU,V)
|
!, (2)
|
2.5.2.5
|
Overflow alarm and shutdown
signal
|
A
|
(AU,V)
|
At an attended location !,
(2)
|
2.5.2.6
|
Loss of power to the alarm
system
|
A
|
(AU,V)
|
!, (2)
|
2.5.2.6
|
Tank level sensor electrical
circuitry failure
|
A
|
(AU,V)
|
!, (2)
|
2.6.4
|
Main vapour collection line
pressure
|
I
|
MI
|
!, (2) VEC is equipped, common to
two or more tanks
|
2.6.4.1
|
High vapour pressure alarm
|
A
|
(AU,V)
|
!, (2) VEC is equipped, common to
two or more tanks
|
2.6.4.2
|
Low vapour pressure alarm
|
A
|
(AU,V)
|
!, (2) VEC is equipped, common to
two or more tanks
|
FSS Code
|
|
|
|
|
15.2.4.2.1.1, 15.2.4.2.2
|
Inert gas pressure
|
I
|
MI
|
|
15.2.4.2.1,2, 15.2.4.2.2
|
Inert gas O2 content
|
I
|
MI
|
|
15.2.4.3.3
|
Inert gas system:
|
A
|
AU,V
|
|
15.2.4.3.1.1
|
- low water pressure/flow
|
A
|
AU,V
|
|
15.2.4.3.1.2
|
- high water level
|
A
|
AU,V
|
|
15.2.4.3.1.3
|
- high gas temperature
|
A
|
AU,V
|
|
15.2.4.3.1.4
|
- blower failure
|
A
|
AU,V
|
|
15.2.4.3.1.5
|
- oxygen content
|
A
|
AU,V
|
|
15.2.4.3.1.6
|
- power supply failure
|
A
|
AU,V
|
|
15.2.4.3.1.7, 15.2.2.4.6
|
- water seal low level
|
A
|
AU,V
|
|
15.2.4.3.1.8, 15.2.4.3.4
|
- low gas pressure
|
A
|
AU,V
|
|
15.2.4.3.1.9
|
- high gas pressure
|
A
|
AU,V
|
|
15.2.4.3.2
|
gas generator failure
|
A
|
AU,V
|
|
15.2.4.3.2.1
|
- low fuel supply
|
A
|
AU,V
|
|
15.2.4.3.2.2
|
- power supply failure
|
A
|
AU,V
|
|
15.2.4.3.2.3
|
- control power
failure
|
A
|
AU,V
|
|
* Cross-reference
to SOLAS regulation.
|
! No location
specified in other IMO instruments. Location is recommended. (2) and (3) See
notes following paragraph 10.2.
|
+ These alarms
may be omitted if they are provided at the pump control.
|
Table 10.1.8 Location: not
indicated by IMO instruments
IMO Instrument
|
Function
|
Priority
|
Display
|
Notes
|
SOLAS II-1
|
|
|
|
|
8.7.3
|
Draught indicator
|
I
|
MI
|
Passenger ships only (if required). For details
see regulation 8.7.3
|
|
|
|
|
Recommended Location: w/h
|
SOLAS II-2
|
|
|
|
|
4.5.10.1.4
|
Pump-room bilge high level alarm
|
A
|
AU,V
|
Recommended Location: w/h or ecr
|
4.5.4.2
|
Flammable vapour monitoring
|
I
|
MI
|
|
Gas or chemical codes
|
|
|
|
|
IBC 7.1.5
BCH 2.15.5(a)
|
Alarm & Monitoring of cargo
temperature
|
A
|
A,V,MI
|
Alert system only required if overheating or
overcooling could result in a dangerous condition
|
|
|
|
|
Recommended Location: w/h or cargo control
station
|
IBC 13.1.1
BCH 3.9
|
Cargo tank levels
|
I
|
MI
|
Recommended Location: cargo control
station
|
IBC 15.7.7
BCH 4.5.7
|
High temperature of phosphorus
|
A
|
AU,V
|
Recommended Location: w/h or cargo control
station
|
2009 MODU Code
|
|
|
|
|
4.10.15
|
Draught indicator
|
I
|
MI
|
At an attended
location II-1/8.7.3*
|
* Cross-reference to SOLAS
regulation.
|
Table 10.1.9 Location: central
ballast control station of column-stabilized MODUs
IMO Instrument
|
Function
|
Priority
|
Display
|
Notes
|
2009 MODU Code
|
|
|
|
|
3.6.5.1
|
Watertight doors and hatch cover position
indicator
|
I,A
|
VI,V
|
|
3.6.5.2
|
Watertight doors and hatch cover position
alarm
|
A
|
AU,V
|
|
4.9.8.1
|
Flooding detector
|
I
|
VI
|
|
4.9.8.3
|
Propulsion room and pump-room bilge high water
level alarm
|
A
|
AU,V
|
|
4.10.10.2
|
Ballast pump status-indicating system
|
I
|
VI
|
For details see also 4.9.12
|
4.10.10.4
|
Ballast valve position-indicating system
|
I
|
VI
|
For details see also 4.9.17
|
4.10.10.5
|
Tank level indicating system
|
I
|
VI
|
For details see also 4.9.14
|
4.10.10.6
|
Draught indicating system
|
I
|
VI
|
For details see also 4.9.15
|
4.10.10.7
|
Heel and trim indicators
|
I
|
VI
|
|
4.10.10.8
|
Main and emergency power available
indication
|
I
|
VI
|
|
4.10.10.9
|
Ballast system hydraulic/pneumatic pressure
indicating system
|
I
|
VI
|
|
4.10.14.1
|
Ballast tanks liquid level
|
I
|
MI
|
|
4.10.14.2
|
Other tanks liquid level
|
I
|
MI
|
|
4.10.17
|
Ballast valve position
|
I
|
VI
|
!
|
|